SO-1856 Pleasant View A/C Addendum 1

MILansing School DistrictschoolOther
Unlock Official Bid Documents — Free 7-Day Trial
Bid Number
--
Open Date
--
Close Date
--
Status
Open

Description

Addendum # 01 PROJECT: SES PROJECT NO: DATE: Lansing Public Schools Pleasantview Air Conditioning 26 0957 01 05/21/2026 The following are changes, clarifications, and additions made to the Specifications and Construction Drawings prior to the receipt of bids and shall be noted by the Contractor responsible for the same. All of these items shall be considered part of the Contract Documents. The general character of the work required by this Addendum shall be the same as originally specified, and all incidentals required in connection with the work hereinafter described shall be included even though not specifically mentioned. The contractor shall be held responsible to include and adjust the work of all trades involved as required to complete the work described hereinafter. All bidders shall review the Addendum as it alters the work shown on the Construction Drawings and the Specifications. Drawings issued: Mechanical: None Electrical: E101 Electrical Drawings: Item No. 1. Refer to sheet E101 (re-issued): A. Added construction note for clarification on conduit routing for the new work. 4000 West Eleven Mile Road | Berkley, MI 48072 | 248.399.1900 | www.sesnet.com SES POWER GENERAL NOTES 1. 2. 3. 4. 5. ALL RECEPTACLES ON EXTERIOR, IN KITCHEN, IN CONCESSION, IN LABORATORY, AND WITHIN 6'-0" OF SINK OR OTHER WATER SUPPLY SHALL BE READILY ACCESSIBLE GFCI TYPE RECEPTACLE. REFER TO ARCHITECTURAL FLOOR PLANS AND ELEVATIONS TO VERIFY LOCATION OF DEVICES. ALL CONDUITS SERVING 120 VOLTS OR GREATER SHALL INCLUDE A GROUND WIRE. ALL CONDUITS SHALL BE ROUTED CONCEALED UNLESS NOTED OTHERWISE. ALL 120 VOLT CIRCUITS SHALL UTILIZE A SEPARATE NEUTRAL. POWER KEYNOTES R1 R2 R3 R4 R5 R6 R7 ELECTRICAL CONTRACTOR TO PROVIDE A 208V, NEMA 6-30R RECEPTACLE. COORDINATE EXACT LOCATION WITH OWNER. PROVIDE SURFACE MOUNTED RACEWAY TO RECEPTACLE; ROUTING TO BE COORDINATED WITH EXISTING FIELD CONDITIONS. EXISTING WALL MOUNTED CONDUIT IN THIS AREA IS DAMAGED. REPLACE BROKEN SERVICE ENTRANCE CONDUIT AS REQUIRED TO REMEDY BROKEN CONDUIT. COORDINATE WITH UTILITY AS REQUIRED FOR FACILITATION OF WORK. CONDUIT IS CRACKED AND CONDUCTORS ARE EXPOSED TO ELEMENTS. NEW PANEL: COORDINATE WITH OWNER FOR EXACT LOCATION IN ROOM. IF THE ROOM HAS OCCUPANCY SENSOR OFF LIGHTING CONTROLS CREATE A NIGHT LIGHT USING EXISTING LIGHTING FIXTURE CLOSEST TO NEW PANEL.

Official Source Link

Unlock the source link for this bid, plus email alerts when similar Other bids open in Michigan. 1,173 open bids in Michigan — see them all with your trial.

Unlock with a 7-day free trial

$49/mo after · cancel anytime

Card required · $0 today

Added May 27, 2026 | ID: 15109842

Open Other Bids in Michigan

MICityOpenTODAY
City of Eastpointe 9 Mile Road Rain Garden Project
Eastpointe · #0145-0818 A
Other
MIStateOpenTODAY
Delta College - Student Resource Center/Library (A Wing)
BidNet Direct - Michigan (MITN)
Other
MICityOpenTODAY
RFQ for Site Plan Reviews
Sturgis · #Site Plan
Other
MIcommunity_collegeOpenTODAY
Delta College - Student Resource Center/Library (A Wing)
Delta College · #2025021 CMC
Other