COMPTON COLLEGE – STUDENT HOUSING Fire Alarm Cutsheets www.p2sinc.com April 2023 P2S Project #J22-0763 4100ES Fire Control Units UL/ULC, CSFM Listed; FM Approved, OTCR/NYC Acceptance* 4100ES Addressable Fire Detection and Control Basic Panel Modules and Accessories Features Figure 1: 4100ES Cabinets are available with one, two, or three bays (two bay cabinet with ES Touch Screen Display shown) Master Controller (top) bay: • Models available with Color ES Touch Screen Display (shown in Figure 1), Monochrome 2 line x 40 Character Display, or Monochrome InfoAlarm Display • 32-Bit Master Controller with color-coded operator interface including raised switches for high-confidence feedback • Dual configuration program CPU, convenient service port access, and capacity for up to 3000 addressable points • CPU assembly includes 2 GB dedicated compact flash memory for onsite system programming and information storage • ES Power Supply (ES-PS) and charger with onboard alarm relay, programmable auxiliary power output and provisions for one 4 in. x 10 in. or two 4 in. x 5 in. compatible option cards such as IDNet2 addressable device interface, Conventional NAC or Addressable IDNAC SLC modules; refer to 579-1288 installation instructions for additional details • Upgrade kits are available for existing control panels Network compatibility: Compatible with Simplex ES Net or 4120 Fire Alarm Networks Standard addressable interfaces include: • 250 point addressable IDNet 2 SLC channel with electrically isolated dual short circuit isolating loops that supports TrueAlarm analog sensors and IDNet communications monitoring and control devices • Remote annunciator module support through RUI+ (remote unit interface) communications port Optional modules include: • Building Network Interface Module (BNIC) for Ethernet connectivity options, refer to data sheet S4100-0061 • Electrically isolated output IDNet 2 (two loop) and IDNet 2+2 (four loop) modules with short circuit isolation output loops allowing use with either shielded or unshielded, twisted or untwisted single pair wiring • Fire Alarm Network Interfaces, DACTs, city connections, and up to five RS-232 ports for printers and terminals • Compatible with Connected Services Gateway to support central station communication and enable SafeLINC Cloud Services, refer to datasheet S2080-0091 • MAPNET II addressable device modules and MAPNET II quad isolator modules • IDNAC signalling line circuits (SLCs) for addressable
Unlock the source link for this bid, plus email alerts when similar Other bids open in California. 4,946 open bids in California — see them all with your trial.
Unlock with a 7-day free trial$49/mo after · cancel anytime
Card required · $0 today