Town of Surfside ITB 2023-01 Abbott Avenue Stormwater Improvements Project Addendum No. 3 Date Issued: March 29, 2023 To All Proposers: Proposers for the above-referenced ITB shall take note of the following changes, additions, deletions or clarifications to ITB No. 2023-01, which in accordance with the ITB Documents shall become a part of and have precedence over anything shown or described otherwise in the ITB. THE FOLLOWING CHANGES ARE MADE TO THE ITB: 1. Please advise if the Underground Utility and Excavation Florida State license will satisfy the bidders qualifications. Updated Response: Yes, but specialty licenses will be required for specialty trades. 2. Please provide details of the FPL points required for the pump stations. Response: Refer to the electrical drawings attached to this addendum and dated 1/2/23. 3. Please provide electrical plans for the pump stations. Response: Refer to the electrical drawings attached to this addendum and dated 1/2/23. 4. Will obtaining building and electrical permits for the pump stations be required? Response: Yes 5. The coatings listed in drawings CP401 and CP-404 (bitumastic 300-M & Mainstay) are designed for sanitary sewer applications; please confirm that they will be required. Response: Will not be required. . PROPOSER: NAME: ____________________________ TITLE: ____________________________ DATE: ____________________________ 1 1 2 4 3 5 UNDERGROUND POWER CONDUIT 301 East Atlantic Blvd. Pompano Beach, FL 33060 PH: (954) 788-3400 ELECTRICAL CIRCUIT RUN EXPOSED 3 FUSED SAFETY SWITCH - NUMBER INDICATES POLES, TRIP AND FRAME - SIZE "O" FOR TRIP INDICATES A NON-FUSED SWITCH 100 75 D T TRANSFORMER H HORN B BELL M MOTOR M.E.EngineeringConsultants,Inc. 11401SW40THStreetSuite301 Ph:(786)275-4635 CA29121 DUPLEX CONVENIENCE OUTLET G.F.I. Florida Engineering Business License: CA7928 Florida Surveyor and Mapper Business License: LB6860 Florida Landscape Architecture Business License: LC26000457 NO. REVISIONS DESCRIPTION DATE GROUND FAULT INTERRUPTER RECEPTACLE J JUNCTION BOX TOGGLE SWITCH ON-OFF TYPE TSW4 Plotted by: me engineering cons On 2/1/2023 5:27 PM SYMBOL-LEGEND: PUSH BUTTON PUSH BUTTON, ON-OFF TYPE, MAINTAINED POSITION. LIMIT SWITCH OVERLOAD TEMPERATURE ACTUATED SWITCH RELAY CONTACT NORMALLY OPEN, CLOSES ON ENERGIZATION, OPENS ON RELAY CONTACT NORMALLY CLOSED, OPENS ON ENERGIZATION, CLOSES ON DE-ENERGIZATION DELTA CONNECTION C PWR. XFMR. 3PH.
Unlock the source link for this bid, plus email alerts when similar Water & Sewer bids open in Florida. 2,474 open bids in Florida — see them all with your trial.
Unlock with a 7-day free trial$49/mo after · cancel anytime
Card required · $0 today