REQUEST FOR QUALIFICATIONS/REQUEST FOR PROPOSAL RFQ/RFP #2627-410 BUILDING AUTOMATION SERVICES PREVENTATIVE MAINTENANCE SERVICES AT SANTIAGO CANYON COLLEGE Addendum No. 1 Issued: October 19, 2026 The following changes, additions, deletions, or corrections shall become part of the above-mentioned RFP: A. The following are responses to questions received: 1. Question: Please clarify whether the selected contractor will be expected to perform programming, firmware updates, database modifications, controller replacement, or manufacturer-level diagnostics on proprietary Automated Logic (ALC) and Alerton field controllers. If so, will the District provide access to all manufacturer-specific software, licenses, passwords, and programming tools required to perform these services? Answer: Yes, the awarded contractor will be granted access to the District’s ALC software to make programming changes. The contractor will be responsible for providing the necessary programming software for the Alerton system. 2. Question: If an ALC or Alerton field controller is diagnosed as failed, is replacement of the controller considered part of the preventative maintenance contract, or will such work be performed under separately authorized repair services and allowance funding? Answer: This work will be considered a repair service, and the district allowance funds may be used to cover the associated costs. 3. Question: Please clarify whether the District requires contractors to maintain active manufacturer dealership or certification status with both Alerton and Automated Logic Controls. Answer: The District requires a minimum of one active certification with either system. However, the selected contractor must have personnel with sufficient experience working with both systems. 4. Question: Please confirm whether the District expects Niagara N4 Supervisor support and BACnet communications troubleshooting only, or full support of all proprietary field controller platforms. Answer: The selected contractor will be responsible for the building control systems and ensuring that all BACnet communications between the controls and the Tridium system are fully functional. However, the contractor will not be responsible for maintaining the N4 system or JACEs. 5. Question: Please clarify which software platforms are included under required software updates and security patching, including Niagara N4, WebCTRL, Alerton software, and Phoenix Controls software.
Unlock the source link for this bid, plus email alerts when similar Other bids open in California. 5,006 open bids in California — see them all with your trial.
Unlock with a 7-day free trial$49/mo after · cancel anytime
Card required · $0 today