Town of Surfside REQUEST FOR PROPOSAL RFP NO. 2020-03 POINT LAKE CANAL SUBAQUEOUS WATER MAIN CROSSING TO BISCAYA ISLAND Addendum No. 3 Date Issued: January 15, 2021 To All Proposers: Proposers for the above-referenced RFP shall take note of the following changes, additions, deletions, clarifications or questions and answers to RFP No. 2020-03, which in accordance with the RFP Documents shall become a part of and have precedence over anything shown or described otherwise in the RFP. THE FOLLOWING CHANGES ARE MADE TO THE RFP: 1. Please advise if ARV’s are required for this project. If yes, please provide pay item. ARVs are not required. 2. Please clarify it an 8”X6” Tee is to be used in lieu of an 8”X6” Reducer for the Fire Hydrant installation. An 8”x6” reducer is required to be cut into the existing 8” main. The new 8” main will be deep at that location, so the plans call for connecting the hydrants to the existing main. 3. In light of the dangers of Covid 19, please advise if the City will accept electronic bids for this project. No, hard copies must be provided. You can mail it or deliver it to the Town Hall. 1 4. Please advise if a 3-member Diving Team is required to be on site during the drilling and pull back of the HDD operation. The Contractor shall adhere to the requirements of the Frac-out Contingency Plan, now made part of the bid documents through this addendum. (See attached document to this addendum) 5. Please advise a field office is required or left up to the discretion of the Contractor. A field office is not required. 6. SECTION 01610, MANUFACTURERS FIELD SERVICES, PART 1 GENERAL DESCRIPTION Provide field services by manufacturer-trained personnel for the duration as specified in the individual equipment sections. Please advise if this section is applicable to this project. If yes, please describe where manufacturer personnel is needed. This section of the specifications is not applicable to this project. 7. 2.02 ENVIRONMENTAL CONTAMINATION It was determined that the project area is in proximity to a few known environmentally contaminated site, as determined by the Miami-Dade County Environmental Considerations website. 8. Please provide location of contamination sites in order to determine the Radius of Influence for the dewatering operation. The locations of the contaminated sites can be viewed on Miami-Dade County’s website here: https://gisweb.miamidade.gov/EnvironmentalConsiderations/ 2 9.
Unlock the source link for this bid, plus email alerts when similar Water & Sewer bids open in Florida. 2,474 open bids in Florida — see them all with your trial.
Unlock with a 7-day free trial$49/mo after · cancel anytime
Card required · $0 today